TZ-WF501BWiFi TemperatureSensor

TZ-WF501BWiFi TemperatureSensor

Product Overview

TZ-WF501 is a WIFI temperature sensor based on IOT technology . It can be widely used in refrigerators, catering, warehouse and HACCP system industries and so on. It
can real-time uploading data to cloud via WIFI . Users can remotely view, monitor, and manage data online via any web browser. At the same time, the device also with flash memory to storage 20,000 temperature recordings. And it can generate PDF report viathe USB port. With a built-in rechargeable lithium backup battery that can provide real-time data uploading and alarm notifications continuously even after power supply cut-off.

Product Overview

TZ-WF501 is a WIFI temperature sensor based on IOT technology . It can be widely used in refrigerators, catering, warehouse and HACCP system industries and so on. It
can real-time uploading data to cloud via WIFI . Users can remotely view, monitor, and manage data online via any web browser. At the same time, the device also with flash memory to storage 20,000 temperature recordings. And it can generate PDF report viathe USB port. With a built-in rechargeable lithium backup battery that can provide real-time data uploading and alarm notifications continuously even after power supply cut-off.

Product Application

Freezer, refrigerator

Greenhouse

Warehouse

Catering, food and HACCP system industries

Pharmacies, biochemical laboratory. etc.

Product Application

Freezer, refrigerator

Greenhouse

Warehouse

Catering, food and HACCP system industries

Pharmacies, biochemical laboratory. etc.

features

WiFi real-time data uploading

Easily to generate PDF report via USB port

High sensitively and precision temperature probe

Keep running up to 30 hours after power supply cut-off

Configurable alarm thresholds, uploading interval and temperature unit

Equipped with buzzer to alarm locally when the temperature and humidity exceedsthe limit

20,000 temperature recordings can be stored into device flash memory, and unlimited reccordings storage on cloud based platform

Equipped with LCD display screen, easily to check current temperature, alarmstatus, battery power and WIFI status

features

WiFi real-time data uploading

Easily to generate PDF report via USB port

High sensitively and precision temperature probe

Keep running up to 30 hours after power supply cut-off

Configurable alarm thresholds, uploading interval and temperature unit

Equipped with buzzer to alarm locally when the temperature and humidity exceedsthe limit

20,000 temperature recordings can be stored into device flash memory, and unlimited reccordings storage on cloud based platform

Equipped with LCD display screen, easily to check current temperature, alarmstatus, battery power and WIFI status

Product Specification

project
Characteristic
Power supply
5V/1A (DC)
Battery
Built in 850mAh / 3.7V battery(rechargeable)
Sensor range
-40℃ to +120℃
Sensor accuracy
Temperature: ±0.3℃(0~60℃), ±0.5 (other) Humidity: ±3% (20~80%), ±4%(other)
Work environment
30℃ to +60℃; 0% RH ~ 85% RH (non condensation)
WiFi
Uploading interval
1 minute to 60 minutes (configurable)
1 minute by default
Low voltage alarm
Support, configurable
Temperature alarm
Support, configurable
IP protection class
IP54
Flash memory capacity
20,000 temperature recordings
Outline specification
106mm*57mm*33mm

Product Specification

project
Characteristic
Power supply
5V/1A (DC)
Battery
Built in 850mAh / 3.7V battery(rechargeable)
Sensor range
-40℃ to +120℃
Sensor accuracy
Temperature: ±0.3℃(0~60℃), ±0.5 (other) Humidity: ±3% (20~80%), ±4%(other)
Work environment
30℃ to +60℃; 0% RH ~ 85% RH (non condensation)
WiFi
Uploading interval
1 minute to 60 minutes (configurable)
1 minute by default
Low voltage alarm
Support, configurable
Temperature alarm
Support, configurable
IP protection class
IP54
Flash memory capacity
20,000 temperature recordings
Outline specification
106mm*57mm*33mm

Working Mode

Working mode
Working condition
Normal mode
The device collects the temperature data at the configured acquisition interval and then enables the module to send the data.
Low voltage alarm mode
When the device voltage is lower than 3.55V(configurable), it will no longer send data, but store the data and send it after the device returns to normal
Temperature alarm mode
When the ambient temperature exceeds the preset limit by user, the device can collect and send data at arelatively faster interval to facilitate users to recordthe changes of ambient temperature

Working Mode

Working mode
Working condition
Normal mode
The device collects the temperature data at the configured acquisition interval and then enables the module to send the data.
Low voltage alarm mode
When the device voltage is lower than 3.55V(configurable), it will no longer send data, but store the data and send it after the device returns to normal
Temperature alarm mode
When the ambient temperature exceeds the preset limit by user, the device can collect and send data at arelatively faster interval to facilitate users to recordthe changes of ambient temperature

LCD Display Description

In shutdown status, the device’s LCD turns off. In startup status, the LCDturns onanddisplays temperature alarm icon, operation status, temperature over limit icon, WiFi
signal strength, battery level , temperature value and humidity value.

project
Characteristic
Temperature alarm icon
Normal: √ Alarm: ×
Operation status
▷ Working status
Temperature over limit icon
Upper limit exceeded: ↑
Lower limit exceeded: ↓
Both upper and lower limits exceeded: ↑↓
WiFi signal strength (RSSI value)
(5 signal line )Very strong signal
(4 signal line ) Strong signal
(3 signal line) Good signal
(2 signal line) General signal
(1 signal line) Poor signal
Battery level
(3 lines)Full battery
(2 line) High battery
(1 line) General battery
(empty) low battery
Temperature value
Unit: Celsius or Fahrenheit optional
Resolution: 0.1,
When the sensor is abnormal, LCDdisplays
Humidity value
Resolution: 0.1,
Show 100% when humidity reaches 100%When the sensor is abnormal,
LCDdisplays---

LCD Display Description

In shutdown status, the device’s LCD turns off. In startup status, the LCDturns onanddisplays temperature alarm icon, operation status, temperature over limit icon, WiFi
signal strength, battery level , temperature value and humidity value.

project
Characteristic
Temperature alarm icon
Normal: √ Alarm: ×
Operation status
▷ Working status
Temperature over limit icon
Upper limit exceeded: ↑
Lower limit exceeded: ↓
Both upper and lower limits exceeded: ↑↓
WiFi signal strength (RSSI value)
(5 signal line )Very strong signal
(4 signal line ) Strong signal
(3 signal line) Good signal
(2 signal line) General signal
(1 signal line) Poor signal
Battery level
(3 lines)Full battery
(2 line) High battery
(1 line) General battery
(empty) low battery
Temperature value
Unit: Celsius or Fahrenheit optional
Resolution: 0.1,
When the sensor is abnormal, LCDdisplays
Humidity value
Resolution: 0.1,
Show 100% when humidity reaches 100%When the sensor is abnormal,
LCDdisplays---

Operating Instruction &Indicatorstatu

On off operation and indicator status

Device status
Operation method
Indicator status
Explanation
Turn-on
Press and hold the button for 3 seconds
It lights green for 5 seconds
Start working
Turn-off
Press and hold the button for 3 seconds
It lights red for 5 seconds
Stop working

To judge device current status by indicator

After startup, if you need to know the device current status, you can check the indicator status
as shown in the table below. If the indicator does not work, it indicates that the device is in shutdownmode. When the device sends data, the indicator will flash once, green light standing for normal
temperature and red light standing for abnormal temperature. The device LED will flash quickly when generating the PDF report, after finished, the LEDwill li
ght in green.The indicator status has priority. The larger the value is, the higher the priority is. The
indicator status is as follows:

Device indicator (green+red)

Device status
LED light
Priority
Network exception
Red light flashes quickly (on for 0.1s and off for 0.1s)
1
Power supply disconnect
Red light flashes slowly (on for 1s and off for 1s)
2
Temperature alarm
Red light is on always
3

Operating Instruction &Indicatorstatu

On off operation and indicator status

Device status
Operation method
Indicator status
Explanation
Turn-on
Press and hold the button for 3 seconds
It lights green for 5 seconds
Start working
Turn-off
Press and hold the button for 3 seconds
It lights red for 5 seconds
Stop working

To judge device current status by indicator

After startup, if you need to know the device current status, you can check the indicator status
as shown in the table below. If the indicator does not work, it indicates that the device is in shutdownmode. When the device sends data, the indicator will flash once, green light standing for normal
temperature and red light standing for abnormal temperature. The device LED will flash quickly when generating the PDF report, after finished, the LEDwill li
ght in green.The indicator status has priority. The larger the value is, the higher the priority is. The
indicator status is as follows:

Device indicator (green+red)

Device status
LED light
Priority
Network exception
Red light flashes quickly (on for 0.1s and off for 0.1s)
1
Power supply disconnect
Red light flashes slowly (on for 1s and off for 1s)
2
Temperature alarm
Red light is on always
3

Buzzer Working Mode

When temperature exceeds the limit, the buzzer rings with bee-bee sound. Situation or operation to stop the buzzer beep:
1. Temperature returns to normal;
2. Short press the button to turn off the buzzer. Note: The buzzer will not ring again until next abnormal temperature (the temperaturereturns to normal first and then abnormal).

Platform Data Query

Temperature & humidity monitoring platform:

Query website:http://t.tzonedigital.cn/
Domain name of TZONE server: t-gateway.tzonedigital.cn
TZONE server port: 54929
After startup, the device’s data can be queried on TZONE platform. When enteringthe platform, you need to register at first, and then add the IMEI number of WiFi501B into “Device Management” of “Basic Settings”. After adding, please wait for a moment because the device sends a real-time data to the server per 1 minute by default.

PDF report data query

PDF report data query